4. DESCRIPTION OF PARAMETERS
B63180EN/02
98
#7
3205
#6 #5 #4 #3 #2 #1
CHG
#0
COL
[Data type] Bit
COL When a program is displayed or output, any colons (:) in the comments of
the program are:
0 : Converted to letter O
1 : Displayed or output as is
CHG When the change function of the extended edit function is used:
0 : Once the user has decided whether to make a change, the cursor is
moved to the target position.
1 : The cursor is moved to the change source, after which the user can
choose whether to make a change.
3216 Increment in sequence numbers inserted automatically
This parameter can be set at Setting screen.
[Data type] Word
[Valid data range] 0 to 9999
Set the increment for sequence numbers for automatic sequence number
insertion (when SEQ, #5 of parameter 0000, is set to 1.)
#7
3230
#6
O48
#5 #4 #3 #2 #1 #0
[Data type] Bit
O48 The program number to be used is:
0 : 4 digits
1 : 8 digits
NOTE
Changing this parameter causes all registered programs to
be erased.
#7
KEY3290
#6
MCM
#5 #4 #3 #2
MCV
#1 #0
[Data type] Bit
MCV Macro variable setting by MDI key input is:
0 : Not disabled
1 : Disabled
MCM The setting of custom macros by MDI key operation is:
0 : Enabled regardless of the mode.
1 : Enabled only in the MDI mode.
KEY For memory protection keys:
0 : The KEY1, KEY2, KEY3, and KEY4 signals are used.
1 : Only the KEY1 signal is used.