PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
99
NOTE
The functions of the signals depend on whether KEY=0 or
KEY=1.
When KEY = 0:
KEY1: Enables a tool offset value to be input.
KEY2: Enables setting data and macro variables to be
input.
KEY3: Enables program registration and editing.
KEY4: Enables PMC data (counter and data table) to be
input.
When KEY = 1:
KEY1: Enables program registration and editing, and
enables PMC parameter input.
KEY2 to KEY4: Not used
#7
3291
#6 #5 #4 #3 #2 #1 #0
WPT
[Data type] Bit
WPT The input of the tool compensation amount is:
0 : Enabled according to memory protection key signal KEY1.
1 : Enabled regardless of memory protection key signal KEY1.