4. DESCRIPTION OF PARAMETERS
105
3622
Number of the pitch error compensation position at extremely positive position
for each axis
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Word axis
[Unit of data] Number
[Valid data range] 0 to 1023
Set the number of the pitch error compensation position at the extremely
positive position for each axis.
NOTE
This value must be larger than set value of parameter
(No.3620).
3623
Magnification for pitch error compensation for each axis
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte axis
[Unit of data] 1
[Valid data range] 0 to 100
Set the magnification for pitch error compensation for each axis.
If the magnification is set to 1, the same unit as the detection unit is used
for the compensation data. If the magnitication is set to 0, the pith error
compensation is not valid.