PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
110
#7
3701
#6 #5 #4 #3 #2 #1
ISI
#0
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
ISI The serial interface for the spindles is:
0 : Used.
1 : Not used.
NOTE
It is used when the CNC is started with serial interface control
for the serial spindles disabled temporarily (for example, for
CNC startup adjustment). Usually, it should be set to 0.
#7
3702
#6 #5 #4 #3 #2
OR1
#1 #0
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
OR1 Whether the stopposition externalsetting type orientation function is
used by the spindle motor
0 : Not used
1 : Used
#7
3705
#6
SFA
#5
NSF
#4 #3
SGT
#2
SGB
#1
GST
#0
ESF
[Data type] Bit
ESF When the spindle control function (Spindle analog outpu or Spindle serial
output) is used, and the constant surface speed control function is used or
bit 4 (GTT) of parameter No.3705 is set to 1:
0 : S codes and SF are output for all S commands.
1 : S codes and SF are not output for an S command in constant surface
speed control mode (G96 mode) or for an S command used to specify
maximum spindle speed clamping.
NOTE
SF is not output:
(1) For an S command used to specify maximum spindle
speed clamping (G92S–––;) in constant surface speed
control mode
(2) When bit 5 (NSF) of parameter No.3705 is set to 1
4.17
PARAMETERS OF
SPINDLE CONTROL

Leave a Reply