PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
3. INPUTTING AND OUTPUTTING
PARAMETERS THROUGH THE
READER/PUNCHER INTERFACE
6
(1) Place the NC in the emergency stop state.
(2) Enable parameter writing.
1. To display the setting screen, press the <OFFSET/SETTING>
function key as many times as required, or alternatively press the
<OFFSET/SETTING> function key once, then the [SETING]
section select soft key. The first page of the setting screen ap-
pears.
2. Position the cursor on PARAMETER WRITE using the cursor
move keys.
3. Press the [(OPRT)] soft key to display operation select soft keys.
4. To set PARAMETER WRITE= to 1, press the ON:1 soft key,
or alternatively enter 1, then press the [INPUT] soft key. From
now on, parameters can be set. At the same time an alarm condi-
tion (P/S100 PARAMETER WRITE ENABLE) occurs in the
NC.
(3) To select the parameter screen, press the <SYSTEM> function key as
many times as required, or alternatively press the <SYSTEM> key
once, then [PARAM] soft key.
(4) Press the [(OPRT)] soft key to display operation select keys, then
press the forward menu key located at the righthand side of the soft
keys to display another set of operation select soft keys including
[READ].
>
EDIT STOP ALM 10:37:30
[ ] [ READ ] [PUNCH] [ ] [ ]
–EMG– ALM
Soft key display
State display
(5) Pressing the [READ] soft key changes the soft key display as shown
below:
>
EDIT STOP ALM 10:37:30
[ ] [ ] [ ] [CANCEL] [ EXEC ]
–EMG– ALM
(6) Press the [EXEC] soft key to start inputting parameters from the
input/output device. When parameters are being input, INPUT
blinks in the state display field on the lower part of the screen.
>
EDIT STOP ALM 10:37:30 INPUT
[ ] [ ] [ ] [CANCEL] [ EXEC ]
–EMG– ALM
INPUT blinking
(7) When parameter input terminates, INPUT stops blinking. Press the
<RESET> key to interrupt parameter input.
(8) When parameter read terminates, INPUT stops blinking, and an
alarm condition (P/S000) occurs in the NC. Turn it off before
continuing operation.