PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
117
3761
Spindle speed when switching from gear 1 to gear 2 during tapping
3762
Spindle speed when switching from gear 2 to gear 3 during tapping
[Data type] Word
[Unit of data] min
1
[Valid data range] 0 to 32767
When method B is selected (SGT,#3 of parameter 3705, is set to 1) for the
tapping cycle gear switching method, set the spindle speed when the gears
are switched.
Max. speed (4095, 10V)
Spindle motor max.
clamp speed
(Parameter No.3736)
Spindle motor minimum
clamp speed
(Parameter No.3735)
Spindle motor speed
Spindle speed
command
(S command)
Gear 1
Max.
speed
Parameter
No.3741
Gear 2
Max.
speed
Parameter
No.3742
Gear 3
Max.
speed
Parameter
No.3743
Gear 12
change point
(Parameter
No.3761)
Gear 23
change point
(Parameter
No.3762)
Fig.4.17 (d) Spindle Motor Speed at Gear 12/23 Change Point during Tapping
3770
Axis as the calculation reference in constant surface speed control
[Data type] Byte
[Valid data range] 1, 2, 3, ..., number of control axes
Set the axis as the calculation reference in constant surface speed control.
NOTE
When 0 is set, constant surface speed control is always
applied to the Xaxis. In this case, specifying P in a G96
block has no effect on the constant surface speed control.