133
5241
Maximum spindle speed in rigid tapping (firststage gear)
5242
Maximum spindle speed in rigid tapping (secondstage gear)
5243
Maximum spindle speed in rigid tapping (thirdstage gear)
[Data type] 2word
[Unit of data] min
1
[Valid data range] Spindle position coder gear ratio
1:1 0 to 7400
1:2 0 to 9999
1:4 0 to 9999
1:8 0 to 9999
Each of these parameters is used to set a maximum spindle speed for each
gear in rigid tapping.
NOTE
Set the same value for both parameter No.5241 and
parameter No.5243 for a onestage gear system. For a
twostage gear system, set the same value for parameter
No.5242 and parameter No.5243. Otherwise, P/S alarm
No.200 will be issued.
5261
Linear acceleration/deceleration time constant for the spindle and tapping axis
(firststage gear)
5262
Linear acceleration/deceleration time constant for the spindle and tapping axis
(secondstage gear)
5263
Linear acceleration/deceleration time constant for the spindle and tapping axis
(thirdstage gear)
[Data type] Word
[Unit of data] ms
[Valid data range] 0 to 4000
Each of these parameters is used to set a linear acceleration/deceleration time
constant for the spindle of each gear and the tapping axis in rigid tapping.
Set the period required to reach each maximum spindle speed (parameters
No.5241 through No.5248). The set time constant, multiplied by the ratio
of a specified S value to a maximum spindle speed, is actually used as a
time constant.