PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
138
5313
Positional deviation limit imposed while the spindle is stopped in rigid tapping
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed while
the spindle is stopped in rigid tapping.
5321
Spindle backlash in rigid tapping
[Data type] Byte
[Unit of data] Detection unit
[Valid data range] 0 to 127
Each of these parameters is used to set a spindle backlash.
5381 Rigid tapping return override
[Data type] Byte
[Unit of data] %
[Valid data range] 0 to 200
This parameter sets a rigid tapping return override value. When 0 is
specified, override is disabled.
NOTE
This parameter is enabled when the bit 4 (DOV) of
parameter No. 5200 for enabling override at the time of
normal extraction is set to 1.
5382 Rigid tapping return amount α
[Data type] Doubleword
[Unit of data] Input unit
[Valid data range] 0 to 99999999
This parameter specifies an extra rigid tapping return amount. The tool is
returned by the extra amount α near point R. If rigid tapping has already
been completed, the tool is returned by α.