PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
141
#7
6000
#6 #5
SBM
#4
HGO
#3 #2 #1
MGO
#0
G67
[Data type] Bit
G67 If the macro continuousstate call cancel command (G67) is specified
when the macro continuousstate call mode (G66) is not set:
0 : P/S alarm No.122 is issued.
1 : The specification of G67 is ignored.
MGO When a GOTO statement for specifying custom macro control is
executed, a highspeed branch to 20 sequence numbers executed from the
start of the program is:
0 : A highspeed branch is not caused to n sequence numbers from the
start of the executed program.
1 : A highspeed branch is caused to n sequence numbers from the start
of the program.
(The number of sequence numbers, n, is set in parameter No.6092.)
HGO When a GOTO statement for specifying custom macro control is
executed:
0 : A highspeed branch is not caused to 30 sequence numbers,
immediately following the point of execution.
1 : A highspeed branch is caused to 30 sequence numbers, immediately
before the point of execution.
SBM Custom macro statement
0: Not stop the single block
1: Stops the single block
NOTE
When parameter No.3404 #0 NOP = 1, it becomes invalid.
#7
CLV6001
#6
CCV
#5
TCS
#4
CRO
#3
PV5
#2
VFP
#1
PRT
#0
[Data type] Bit
PRT Reading zero when data is output using a DPRINT command
0 : Outputs a space
1 : Outputs no data
VFP The tape output format to be used for common variables is:
0 : Custom macro statement format
1 : The same format as for the Power MateA, B, and C
PV5 Custom macro common variables:
0 : Nos. 500 to 599 are output.
1 : Nos. 100 to 199 and Nos. 500 to 599 are output.
CRO ISO code in BPRWT or DPRNT commond
0 : Outputs only LF after data is output
1 : Outputs LF and CR after data is output
TCS Custom macro (subprogram)
0 : Not called using a T code
1 : Called using a T code
4.23
PARAMETERS OF
CUSTOM MACROS