PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
144
6050 G code that calls the custom macro of program number 9010
6051 G code that calls the custom macro of program number 9011
6052 G code that calls the custom macro of program number 9012
6053 G code that calls the custom macro of program number 9013
6054 G code that calls the custom macro of program number 9014
6055 G code that calls the custom macro of program number 9015
6056 G code that calls the custom macro of program number 9016
6057 G code that calls the custom macro of program number 9017
6058 G code that calls the custom macro of program number 9018
6059 G code that calls the custom macro of program number 9019
[Data type] Word
[Valid data range] 1 to 999
These parameters set the G codes that call the custom macros of program
numbers 9010 through 9019.
NOTE
Setting value 0 is invalid. No custom macro can be called by
G00.
6071 M code that calls the subprogram of program number 9001
6072 M code that calls the subprogram of program number 9002
6073 M code that calls the subprogram of program number 9003
6074 M code that calls the subprogram of program number 9004
6075 M code that calls the subprogram of program number 9005
6076 M code that calls the subprogram of program number 9006
6077 M code that calls the subprogram of program number 9007
6078 M code that calls the subprogram of program number 9008
6079 M code that calls the subprogram of program number 9009
[Data type] 2word
[Valid data range] 1 to 99999999
These parameters set the M codes that call the subprograms of program
numbers 9001 through 9009.
NOTE
Setting value 0 is invalid. No custom macro can be called by
M00.