4. DESCRIPTION OF PARAMETERS
B63180EN/02
146
When bit 3 (SFM) of parameter No. 3109 is set to 0
(1) Pressing
OFFSET
SETTING
displays page 1 of soft keys.
[OFFSET] [SETTING] [ ] [ ] [(OPRT)]
(2) Pressing the next page soft key ( ) displays page 2 of soft keys.
[MACRO] [ MENU ] [ ] [ ] [(OPRT)]
(3) Pressing the menu soft key displays the menu screen.
When bit 3 (SFM) of parameter No. 3109 is set to 1
(1) Pressing
OFFSET
SETTING
displays page 1 of soft keys.
This screen displays the menu soft key.
[OFFSET] [SETTING] [ ] [ MENU ] [(OPRT)]
(2) Pressing the menu soft key displays the menu screen.
6101 Variable number 1 first displayed on the pattern data screen 1
:
6110 Variable number 1 first displayed on the pattern data screen 10
[Data type] Word
[Valid data range] 0, 100 to 199, 500 to 699
Variable number first displayed on the pattern data screen selected on the
menu screen of the pattern data input function (displayed on the screen for
each multiple of 8). When 0 is specified, a specification of 500 is assumed.
Example: Macro variables starting with No. 508 are displayed if 508 is
set in parameter No. 6101, and pattern 1 is selected on the
pattern data menu screen.
4.24
PARAMETERS OF
PATTERN DATA
INPUT