PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
154
NOTE
The change to this setting takes effect next time the power
is turned on.
6230
Axis number of an axis assigned to buffer 1
6231
Axis number of an axis assigned to buffer 2
6232
Axis number of an axis assigned to buffer 3
6233
Axis number of an axis assigned to buffer 4
6234
Axis number of an axis assigned to buffer 5
6235
Axis number of an axis assigned to buffer 6
6236
Axis number of an axis assigned to buffer 7
6237
Axis number of an axis assigned to buffer 8
[Data type] Byte
[Valid data range] 1 to 8
If highspeed skip signals specified in parameters 6220 to 6227 are input,
the coordinates of the axes specified in these parameters are stored to the
respective buffers.
If a value out of the valid data range is specified for a parameter, the
parameter is invalid.
NOTE
The change to this setting takes effect next time the power
is turned on.