PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
155
6240
Compensation value for signal 1
6241
Compensation value for signal 2
6242
Compensation value for signal 3
6243
Compensation value for signal 4
6244
Compensation value for signal 5
6245
Compensation value for signal 6
6246
Compensation value for signal 7
6247
Compensation value for signal 8
[Data type] Word
[Unit of data] ms
[Valid data range] 0 to 8000
A signal delay that may occur in some sensors for the highspeed skip
signalbased measurement function is set up as a compensation value.
If a value out of the valid data range is specified for a parameter, the
parameter is invalid.
NOTE
The change to this setting takes effect next time the power
is turned on.