159
6752 Operation time (integrated value of time during automatic operation) II
This parameter can be set at Setting screen.
[Data type] 2word
[Unit of data] One minute
[Valid data range] 0 to 99999999
This parameter displays the integrated value of time during automatic
operation (neither stop nor hold time included).
6753 Integrated value of cutting time I
This parameter can be set at Setting screen.
[Data type] 2word
[Unit of data] One ms
[Valid data range] 1 to 60000
6754 Integrated value of cutting time II
This parameter can be set at Setting screen.
[Data type] 2word
[Unit of data] One minute
[Valid data range] 0 to 99999999
This parameter displays the integrated value of a cutting time that is
performed in cutting feed such as linear interpolation (G01) and circular
interpolation (G02 or G03).
6755
Integrated value of generalpurpose integrating meter drive signal (TMRON)
ON time I
This parameter can be set at Setting screen.
[Data type] 2word
[Unit of data] One ms
[Valid data range] 0 to 60000
6756
Integrated value of generalpurpose integrating meter drive signal (TMRON)
ON time II
This parameter can be set at Setting screen.
[Data type] 2word
[Unit of data] One minute
[Valid data range] 0 to 99999999
This parameter displays the integrated value of a time while input signal
TMRON from PMC is on.