PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
163
#7
7100
#6 #5 #4
HPF
#3
HCL
#2
IHD
#1
THD
#0
[Data type] Bit
THD Manual pulse generator in TEACH IN JOG mode
0 : Invalid
1 : Valid
IHD The travel increment for manual handle interrupt is:
0 : Output unit, and acceleration/deceleration after interpolation is
disabled.
1 : Input unit, and acceleration/deceleration after interpolation is
enabled.
HCL The clearing of handle interruption amount display by soft key [CAN]
operation is:
0 : Disabled.
1 : Enabled.
HPF When a manual handle feed exceeding the rapid traverse rate is issued,
0 : The rate is clamped at the rapid traverse rate, and the handle pulses
corresponding to the excess are ignored. (The graduations of the
manual pulse generator may not agree with the distance the machine
has traveled.)
1 : The rate is clamped at the rapid traverse rate, and the handle pulses
corresponding to the excess are not ignored, but stored in the CNC. (If
the rotation of the manual pulse generator is stopped, the machine
moves by the distance corresponding to the pulses preserved in the
CNC, then stops.)
#7
7101
#6 #5 #4 #3 #2 #1 #0
IOL
[Data type] Bit
IOL 0 : As a manual pulse generator interface for manual handle feed, the
manual pulse generator interface on the base PCB is used.
1 : As a manual pulse generator interface for manual handle feed, the
manual pulse generator interface of the machine operators panel
interface for I/O Link is used.
#7
7102
#6 #5 #4 #3 #2 #1 #0
HNGx
[Data type] Bit axis
HNGx Axis movement direction for rotation direction of manual pulse generator
0 : Same in direction
1 : Reverse in direction
4.31
PARAMETERS OF
MANUAL HANDLE
FEED, HANDLE
INTERRUPTION
DIRECTION

Leave a Reply