4. DESCRIPTION OF PARAMETERS
B63180EN/02
164
#7
7104
#6
NJH
#5 #4 #3 #2 #1 #0
[Data type] Bit
NJH Manual handle feed in the jog mode and incremental feed in the manual
handle feed mode are:
0 : Enabled.
1 : Disabled.
When NJH is set to 1 When NJH is set to 0
Jog feed
mode
Manual
handle feed
mode
Jog feed
mode
Manual
handle feed
mode
Jog feed Ę Ę
Manual handle
feed
Ę Ę Ę
Incremental
feed
Ę
NOTE
If this bit is 1 when you to want perform butttype reference
position setting for more than one axis continuously, you do
not need to turn the power off and on again each time
reference position setting is performed each axis. When
butttype reference position setting is performed for an axis,
alarm 000 is issued, but butttype reference position setting
can be performed for another axis. (In this case, however,
if you reset the machine or switch from one mode to another,
you must turn the power off and on again before you can
perform butttype reference position setting for another
axis.)
7110 Number of manual pulse generators used
[Data type] Byte
[Valid data range] 1, 2 (up to 3 if a manual pulse generators on the I/O Link machine
operators panel interface are used in the Power Mate iH)
This parameter sets the number of manual pulse generators.
7113 Manual handle feed magnification m
[Data type] Word
[Unit of data] One time
[Valid data range] 1 to 127
This parameter sets the magnification when manual handle feed
movement selection signal MP2 is set to 1.