4. DESCRIPTION OF PARAMETERS
B63180EN/02
168
#7
7200
#6
OP7
#5
OP6
#4
OP5
#3
OP4
#2
OP3
#1
OP2
#0
OP1
[Data type] Bit
OP1 Mode selection on software operators panel
0 : Not performed
1 : Performed
OP2 JOG feed axis select and JOG rapid traverse buttons on software
operators panel
0 : Not performed
1 : Performed
OP3 Manual pulse generators axis select and manual pulse generators
magnification switches on software operators panel
0 : Not performed
1 : Performed
OP4 JOG speed override and rapid traverse override switches on software
operators panel
0 : Not performed
1 : Performed
OP5 Optional block skip, single block, machine lock, and dry run switches on
software operators panel
0 : Not performed
1 : Performed
OP6 Protect key on software operators panel
0 : Not performed
1 : Performed
OP7 Feed hold on software operators panel
0 : Not performed
1 : Performed
#7
NS07202
#6
NS2
#5 #4 #3 #2 #1 #0
[Data type] Bit
NS2 0 : Uses the software operators panel generalpurpose switches.
1 : Does not use the software operators panel generalpurpose switches.
NS0 0 : Uses the software operators panel.
1 : Does not use the software operators panel.
4.33
PARAMETERS OF
SOFTWARE
OPERATORS PANEL