PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
172
#7
EXH7670
#6 #5 #4 #3 #2 #1 #0
[Data type] Byte
EXH 0 : Sets an axis and magnification for external pulse input by using DI
signals
1 : Sets an axis and magnification for external pulse input by using
parameters
7681 Setting 1 of the ratio of an axis move amount to external pulses (M)
[Data type] Byte
[Valid data range] M = 1 to 255
NOTE
This parameter is valid when bit 7 (EXH) of parameter
No.7670 is set to 1.
7682 Setting 2 of the ratio of an axis move amount to external pulses (N)
[Data type] Word
[Valid data range] N = 1 to 1000
NOTE
This parameter is valid when bit 7 (EXH) of parameter
No.7670 is set to 1.
#7
7701
#6 #5 #4 #3 #2
SM3
#1
SM2
#0
SM1
SM3 SM2 SM1
Number of
sampling operations
0 0 0 4
0 0 1 1
0 1 0 2
0 1 1 8
1 0 0 16
1 0 1 4
1 1 0 4
1 1 1 4
Specify the number of sampling operations for input pulse smoothing.