PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
173
7710 Setting of an axis number for movement along an axis by external pulses
[Data type] Byte
[Valid data range] 1, 2, ..., number of controlled axes
If 0 is specified, no movement along an axis is made by external pulses.
NOTE
This parameter is valid when bit 7 (EXH) of parameter
No.7670 is set to 1.
7712
Time constant of acceleration/deceleration for an external pulsebased axis
(exponential acceleration/deceleration)
[Data type] Word
[Unit of data] ms
[Valid data range] 0 to 4000
7713 FL feedrate for acceleration/deceleration for an external pulsebased axis
[Data type] Word
[Unit of data]
[Valid data range]
Range of valid data
Unit of data
ISB ISC
deg/min
6 to 15000 6 to 12000
NOTE
When the 2path Power Mate iD is used, the external pulse
input function can be used only with the first path side.

Leave a Reply

Your email address will not be published. Required fields are marked *