4. DESCRIPTION OF PARAMETERS
B63180EN/02
12
The parameters described below must be set up to use an I/O unit interface
(RS232C serial port), remote buffer interface, or memory card interface
for inputting and outputting data (such as programs and parameters)
between external input/output units and memory cards.
The I/O CHANNEL setting parameter is used to select a desired
input/output unit by specifying the channel (RS232C serial port 1,
RS232C serial port 2, or remote buffer interface) to which the
input/output unit is connected. This is true also when the memory
interface is used.
The specified data, such as a baud rate and the number of stop bits, of an
input/output device connected to a specific channel of I/O device interface
must be set in parameters for that channel in advance.
For channel 1, two combinations of parameters to specify the input/output
device data are provided.
The following shows the interrelation between the input/output device
interface parameters for the channels of I/O device interface.
Stop bit and other data
Number specified for the input/
output device
Baud rate
Stop bit and other data
Number specified for the input/
output device
Baud rate
Stop bit and other data
Number specified for the input/
output device
Baud rate
I/ O CHANNEL
=0 : Channel1
=1 : Channel1
=2 : Channel2
Specify a channel for an in-
put/output device.
I/O CHANNEL=1
(channel 1)
0020
0101
0102
I/O CHANNEL=0
(channel 1)
0103
0111
0112
0113
0121
0122
I/O CHANNEL=2
(channel 2)
0123
I/O CHANNEL
Input/output channel number (parameter No.0020)
Fig.4.2 I/O Device Interface Settings
4.2
PARAMETERS OF
READER/PUNCHER
INTERFACE