PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
180
#7
8081
#6 #5 #4 #3
EXD
#2
TYB
#1 #0
ECM
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
ECM The electronic cam function is:
0 : Not used.
1 : Used.
TYB The specification of the electronic cam is:
0 : A
1 : B
EXD The number of cam figure data items is:
0 : Not increased.
1 : Increased.
CAUTION
If you change the setting of this parameter, you need to clear
the tape storage area. Before clearing it, back up the part
program. To clear, hold down the <DELETE> key and turn
on the power.
#7
8082
#6 #5 #4 #3 #2 #1
NCP
#0
[Data type] Bit
NCP In the electronic cam function, phase matching is:
0 : Used.
1 : Not used.
NOTE
If you want to connect the cam shaft to a tracking axis or
disconnect them during electronic cam operation, set this
parameter to 1.