4. DESCRIPTION OF PARAMETERS
B63180EN/02
184
8290
Device number
[Data type] Word axis
Set the device number for a device to which pulses are to be applied
manually.
This parameter is reserved for future expansion. Set the values listed
below for the time being.
First axis 1
Second axis 2
Third axis 3
Fourth axis 4
Fifth axis 5
Sixth axis 6
Seventh axis 7
Eighth axis 8
8291
Type of device
[Data type] Word axis
Set the type of a device to which pulses are to be applied manually.
A value of 5 (device step signal) should be set for an axis for which device
input is to be performed.
Device type Category number
Device step signal 5
8292
Device axis magnification M
[Data type] Word axis
[Valid data range] -30000 to 30000
Set a magnification M for a device to which pulses are to be applied
manually.
The magnification satisfies the following expression.
Pulses (P) input for a controlled axis = pulses for the device M
If 0 or any value out of the valid data range is specified, a magnification
of 1 is assumed.
The maximum pulse count for the device is 32767 pulses, and the
minimum pulse count is 32767 pulses. If P is greater than 32767,
therefore, the actual pulse count is clamped at 32767.
4.38
PARAMETERS OF
DEVICE INPUT