4. DESCRIPTION OF PARAMETERS
B63180EN/02
186
#7
SOF8301
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
SOF The synchronization funciton in simple synchronous control (one pair) is:
0 : Not used.
1 : Used.
#7
8302
#6 #5 #4 #3 #2 #1
ATS
#0
ATE
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
ATE Automatic setting of grid positioning for simplified synchronous control
one pair is:
0 : Disabled
1 : Enabled
ATS Automatic setting of grid positioning for simplified synchronous control
one pair is:
0 : Not started
1 : Started
NOTE
1 When the bits are set to 1, parameter No.8316 and bit 4
(APZx) of parameter No.1815 for the master and slave axes
are set to 0.
2 These bits are automatically set to 0 once grid positioning
has been completed.
#7
SFX8303
#6 #5 #4 #3 #2 #1
ASX
#0
AEX
NOTE
After this parameter has been set, the power must be turned
off then on again for the setting to become effective.
[Data type] Bit axis
AEX In simple synchronous control, automatic setting for grid positioning is:
0 : Disabled.
1 : Enabled.
ASX In simple synchronous control, automatic setting for grid positioning is:
0 : Not started.
1 : Started.