4. DESCRIPTION OF PARAMETERS
193
#7
A088508
#6
A07
#5
A06
#4
A05
#3
A04
#2
A03
#1
A02
#0
A01
A168509 A15 A14 A13 A12 A11 A10 A09
[Data type] Bit
A01 to A16 The signal is turned on when the corresponding highspeed position
switch passes through the machine coordinate position set in parameter
No. 8550 to 8565:
0 : In the negative () direction.
1 : In the positive (+) direction.
When decision by direction is selected for the output type of a highspeed
position switch in parameter No. 8550 to 8565, the corresponding
parameter sets the direction.
The twodigit number in each parameter name represents the sequence of
the highspeed position switch.
For ordinary highspeed position switches, it is unnecessary
to set up this parameter.
#7
B088512
#6
B07
#5
B06
#4
B05
#3
B04
#2
B03
#1
B02
#0
B01
B168513 B15 B14 B13 B12 B11 B10 B09
[Data type] Bit
B01 to B16 The signal is turned off when the corresponding highspeed position
switch passes through the machine coordinate position set in parameter
No. No.8580 to 8595:
0 : In the negative () direction.
1 : In the positive (+) direction.
When decision by direction is selected for the output type of a highspeed
position switch in parameter No.8580 to 8595, the corresponding
parameter sets the direction.
The twodigit number in each parameter name represents the sequence of
the highspeed position switch.
For ordinary highspeed position switches, it is unnecessary
to set up this parameter.