PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
200
[Data type] Twoword
[Unit of data]
Increment system ISA ISB ISC Unit
Millimeter machine
0.01 0.001 0.0001 mm
Inch machine
0.001 0.0001 0.00001 inch
Rotation axis
0.01 0.001 0.0001 deg
[Valid data range] 99999999 to 99999999
For normal type
Minimum value (machine coordinate value) of the operation range of
the first to sixteenth highspeed position switches
If you make such a setting which causes the maximum value is less
than the minimum value, the range of operation is narrowed, making
the highspeed position switched inoperable.
For direction reversing type
Position where the first to sixteenth position switches are turned off
The highspeed position switches change their states only when the
tool passes these machine coordinates in the direction specified in
parameter Nos. 8512 and 8513 (bit).
NOTE
The same parameters are used to set the lower limit for the
operation range of the ordinary highspeed position
switches and the machine coordinates where the decision
bydirection highspeed position switches become OFF.
Be careful not to make incorrect settings.

Leave a Reply

Your email address will not be published. Required fields are marked *