PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
203
NOTE
The change is put in effect next time the power is turned on.
#7
8701
#6 #5 #4 #3 #2
WPR
#1
PLD
#0
[Data type] Bit
PLD When the Pcode loader function is used (macro compiler/executor):
0 : AM is initialized and the entire contents of RAM are rewritten.
1 : RAM is not initialized, being overwritten instead
WPR The function that allows parameters that are rewritten using the PMC
window to be enabled during automatic operation is:
0 : Disabled.
1 : Enabled.
#7
8705
#6 #5 #4 #3 #2 #1
ADC
#0
[Data type] Bit
ADC 0 : Does not use the analog input module.
1 : Uses the analog input module.
#7
8706
#6 #5
CPL
#4
HMD
#3 #2 #1 #0
[Data type] Bit
CPL In the highspeed response function, the signalbased compile function is:
0 : Not used.
1 : Used.
HMD In the highspeed response function, an auxiliary function is:
0 : Not used.
1 : Used.
8730 Input voltage offset for the analog input module
[Data type] Word
[Unit of data] 1.22 mV
[Valid data range] 0 to +8191
This parameter specifies an offset for a voltage applied from the analog
input module. Specify 0 V so that the value of diagnostic data No. 833
becomes 0.