PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
204
#7
8731
#6
EP6
#5
EP5
#4
EP4
#3
EP3
#2
EP2
#1
EP1
#0
EP0EP7
[Data type] Bit
EPn The highspeed skip signal (bit n of X1003) is used:
0 : With the highspeed skip signalbased measurement function
1 : As an interrupt type PMC trigger
NOTE
1 The change is put in effect next time the power is turned on.
2 The same signal cannot be used with the highspeed
skipbased measurement function and the interrupt type
PMC function simultaneously.
#7
8732
#6
UP6
#5
UP5
#4
UP4
#3
UP3
#2
UP2
#1
UP1
#0
UP0UP7
[Data type] Bit
UPn The positivegoing edge (0 R 1) of the highspeed skip signal (bit n of
X1003) is:
0 : Disabled as an interrupt for the interrupt type PMC or as a highspeed
skip signal.
1 : Enabled as an interrupt for the interrupt type PMC or as a highspeed
skip signal.
NOTE
The change is put in effect next time the power is turned on.
#7
8733
#6
DN6
#5
DN5
#4
DN4
#3
DN3
#2
DN2
#1
DN1
#0
DN0DN7
[Data type] Bit
DNn The negativegoing edge (1 R 0) of the highspeed skip signal (bit n of
X1003) is:
0 : Disabled as an interrupt for the interrupt type PMC or as a highspeed
skip signal.
1 : Enabled as an interrupt for the interrupt type PMC or as a highspeed
skip signal.
NOTE
The change is put in effect next time the power is turned on.