PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
207
8781 Size of DRAM used by FAPT PICTURE or C executor
[Data type] Byte
[Unit of data] 64 Kbytes
[Valid data range] 16 to 128
Set the size of DRAM used by FAPT PICTURE or C executor.
If a specified value is out of the valid data range, 0 is assumed.
The following table lists the relationships between the parameter values
and a combination of C executor options and FAPT PICTURE
Setting
value
C language
executor
Additional
capacity for C
executor
program
capacity, 1 MB
Additional
capacity for C
executor
program
capacity, 2 MB
Touch panel
control
(FAPT
PICTURE)
16 Ę
32 Ę Ę
48 Ę Ę
96 Ę
96 Ę Ę
112 Ę Ę Ę
128 Ę Ę Ę
NOTE
1 When this parameter is set, the power must be turned off
before operation is continued.
2 The size of DRAM that can be used actually is limited by the
DRAM capacity and what option is installed.
8790 Timing for executing an auxiliary macro
[Data type] Word
[Unit of data]
This parameter sets the timing for executing a macro executor auxiliary
macro while NC programs, offset data, and so forth are being read or
punched out.
When as many characters as the number specified with this parameter are
read or punched out, an auxiliary macro is executed once. When 0 is set in
this parameter, no auxiliary macro is executed during read or punch
processing.