0171 Length of DI data in bytes
[Data type] Byte
[Valid data range] 1 to 32
Set the length (in bytes) of the DI (actual transfer data) to be sent from the
master station to the Power Mate iD/H. A specified number of bytes of
DI data from the PMC area will be stored.
0172 Length of DO data in bytes
[Data type] Byte
[Valid data range] 1 to 32
Set the length (in bytes) of the DO (actual transfer data) to be sent from the
Power Mate iD/H to the master station. A specified number of bytes of
DO data from the PMC area will be output.
0173 Station address
[Data type] Byte
[Valid data range] 1 to 31
Specify a station address.
0174 Baud rate
[Data type] Byte
[Valid data range] 0 to 3
Set the baud rate to be used in communication.
Setting
value
Baud rate
0 1 Mbps
1 500 kbps
2 250 kbps
3 125 kbps
0180
The maximum number of slave stations from which the station of interest can re-
ceive data using the global I/O transfer function (the station of interest is included)
[Data type] Byte
[Valid data range] 0 to 31
0 : Specifies that the global I/O transfer function be not used.
1 to 31 : Specify that the number of slave stations from which the station
of interest receives data using the global I/O (the station of
interest is included). The input/output data is sent to the R area.