PDF Fanuc Power Mate i-D/H Parameter Manual

A
dd the following description in the chapter “4.31 Others”.
No. 7 6 5 4 3 2 1 0
8850 MDG
Data type: bit
MDG Trouble diagnosis function is:
0:Available.
1:Not available.
No. 7 6 5 4 3 2 1 0
8853 TRS8 TRS7 TRS6 TRS5 TRS4 TRS3 TRS2 TRS1
Data type: bit
TRS1 - TRS8 Trouble forecast of thermal simulation of servo axis is:
0:Not available.
1:Available.
No. 7 6 5 4 3 2 1 0
8854 FIN8 FIN7 FIN6 FIN5 FIN4 FIN3 FIN2 FIN1
Data type: bit
FIN1 – FIN8 Trouble forecast of disturbance torque of servo axis is:
0:Not available.
1:Available.
No.
8860 Trouble forecast level for thermal simulation
Data type: WORD AXIS
Data unit: %
Data Range: 0 - 100%
8861 Trouble forecast level for disturbance torque
Data type: WORD AXIS
Data unit: %
Data Range: 0 - 100%