4. DESCRIPTION OF PARAMETERS
B63180EN/02
18
#7
0370
#6 #5 #4 #3 #2 #1 #0
PC1
[Data type] Bit
PC1 PC1 If the DPL/MDI Operation Package is connected, the CRT display
screen displays:
0 : Absolute coordinates and machine coordinates (using fullsize
characters)
1 : Only absolute coordinates (using triplesize characters)
NOTE
If seven or more controlled axes are used, even setting this
parameter to 1 causes the display screen to look the same
as when the parameter is set to 0.
0380
Time interval at which packets requesting to establish DPL/MDI Operation
Package communication are to be sent
[Data type] Word
[Unit of data] msec
[Valid data range] 1000 to 10000 (Usually, set 0, in which case a setting value of 3000 is
assumed.)
0381
Time interval at which packets for verifying the connection of DPL/MDI Opera-
tion Package are to be sent
[Data type] Word
[Unit of data] msec
[Valid data range] 1000 to 10000 (Usually, set 0, in which case a setting value of 5000 is
assumed.)
0382 Timeout value used in waiting for a DPL/MDI Operation Package response packet
[Data type] Word
[Unit of data] msec
[Valid data range] 1000 to 30000 (Usually, set 0, in which case a setting value of 5000 is
assumed.)
4.4
PARAMETERS OF
DPL/MDI OPERATION
PACKAGE