PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
19
0383 Time allowed before a DPL/MDI Operation Package key input repetition is detected
[Data type] Word
[Unit of data] msec
[Valid data range] 100 to 3000 (Usually, set 0, in which case a setting value of 1000 is
assumed.)
Time allowed before the first key repetition is detected
0384 Time allowed before a DPL/MDI Operation Package key input repetition is detected
[Data type] Word
[Unit of data] msec
[Valid data range] 10 to 3000 (Usually, set 0, in which case a setting value of 30 is assumed.)
Time allowed before the second or each subsequent key repetition is
detected
NOTE
If the CPU of the PC is occupied by an application other than
the DPL/MDI Operation Package or the OS for a long time,
the Power Mate may automatically disconnect the DPI/MDI
Operation Package. In this case, you should terminate the
DPL/MDI Operation Package application on the PC side
and restart it (it will be automatically reconnected). If this
symptom reoccurs frequently, increase the values of
parameter Nos. 381 and 381 until the symptom will reoccur
no more.

Leave a Reply