PDF Fanuc Power Mate i-D/H Parameter Manual

EDIT
DATE DISIGNE
DESCRIPTION
TITLE
DRAW
FANUC Power Mate i -MODEL D/H
The function of feedrate override and feedrate
override cancel for each axis group in the
PMC axis control
B-63180EN/02-12
SHEET
2/2
APPROV.
FANUC LTD
030207
01
New design
Add the following description to 4. Description of Parameters.
[Data type] Bit type
IOVC Signal for override cancel used in the PMC axis control
0 : is common signal for all group
1 : is each signal for each group
INOV Signal for feedrate override used in the PMC axis control
0 : is common signal for all group
1 : is each signal for each group
8009
#7 #6 #5 #4 #3 #2 #1 #0
INOV IOVC
Note
When parameter No. 8009#0(IOVC) or 8009#1(INOV) is set to 0, each
signal of override cancel and feedrate override can be selected to use
same signals used for the CNC or signals specific to the PMC by setting
of parameter No. 8001#2(OVE).