B63180EN/02
4. DESCRIPTION OF PARAMETERS
23
#7
0960
#6 #5
ASG
#4
SPW
#3
PMN
#2
MD2
#1
MD1
#0
SLV
[Data type] Bit
SLV When the power mate CNC manager is selected, the screen displays:
0 : One slave.
1 : Up to four slaves with the screen divided into four.
MD1,MD2
These parameters set a slave parameter input/output destination.
MD2 MD1 Input/output destination
0 0 Part program storage
0 1 Memory card
In either case, slave parameters are output in program format.
PMN The power mate CNC manager function is:
0 : Enabled.
1 : Disabled. (Communication with slaves is not performed.)
SPW Slave parameter setting by power mate CNC manager:
0 : Is always enabled.
1 : Conforms to Parameter Writing (PWE) in parameter setting.
ASG Whether the number of bytes assigned to the B amplifier input/output I/O
address is 16 bytes will:
0 : Not be checked.
1 : Be checked.