PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
29
1010 Number of CNCcontrolled axes
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Byte
[Valid data range] 1, 2, 3, ..., the number of controlled axes
Set the maximum number of axes that can be controlled by the CNC.
Suppose that the first axis is the X axis, and the second and subsequent
axes are the Y, Z, A, B, and C axes in that order, and that they are
controlled as follows:
X, Y, Z, and A axes: Controlled by the CNC and PMC
B and C axes: Controlled by the PMC
Then set this parameter to 4 (total 4: X, Y, Z, and A)
1011 Number of controlled axes
NOTE
After this parameter has been set, the power must be turned
off then back on to enable the setting.
[Data type] Byte
[Valid data range] 1 or 2 (Power Mate iD)
1 to 8 (Power Mate iH)
This parameter specifies the maximum number of controlled axes. If 0 or
a value exceeding the specifiable range of valid data is specified, alarm
5150 is issued.
#7
1012
#6 #5 #4 #3 #2 #1 #0
IDGx
[Data type] Bit axis
IDGx The function for setting the reference position again, without dogs, is:
0 : Not inhibited.
1 : Inhibited.
Examples

Leave a Reply