PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
37
#7
1401
#6
RDR
RDR
#5
TDR
#4
RF0
RF0
#3 #2 #1
LRP
LRP
#0
RPD
RPD
[Data type] Bit
RPD Manual rapid traverse during the period from poweron time to the
completion of the reference position return.
0: Disabled (Jog feed is performed.)
1: Enabled
LRP Positioning (G00)
0: Positioning is performed with nonlinear type positioning so that the
tool moves along each axis independently at rapid traverse.
1: Positioning is performed with linear interpolation so that the tool
moves in a straight line.
RF0 When cutting feedrate override is 0% during rapid traverse,
0: The machine tool does not stop moving.
1: The machine tool stops moving.
TDR Dry run during tapping (tapping cycle G74 or G84, rigid tapping)
0: Enabled
1: Disabled
RDR Dry run for rapid traverse command
0: Disabled
1: Enabled
#7
1404
#6 #5 #4 #3 #2
F8A
#1
DLF
#0
[Data type] Bit
DLF After a reference potition is set, manual reference position return
performed at:
0 : Rapid traverse rate (parameter No.1420)
1 : Manual rapid traverse rate (parameter No.1424)
NOTE
This parameter selects a feedrate for reference position
return performed without dogs. This parameter also selects
a feedrate when manual reference position return is
performed according to bit 7 (SJZ) of parameter No.0002
using rapid traverse without deceleration dogs after a
reference position is set.
F8A Valid data range for an F command with a decimal point in feedper
minute mode
Increment system Units ISA, ISB ISC
Millimeter input mm/min 0.001 to 99999.999.
Inch input inch/min 0.00001 to 999.99999.
Rotation axis (mm) deg/min 1 to 240000. 1 to 100000.
Rotation axis (inch) deg/min 1 to 9600. 1 to 4000.
4.10
PARAMETERS OF
FEEDRATE
0: