PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
38
Increment system Units ISA, ISB ISC
Millimeter input mm/min 0.001 to 240000. 0.001 to 100000.
Inch input inch/min 0.00001 to 9600. 0.00001 to 4000.
Rotation axis deg/min 1 to 240000. 1 to 100000.
#7
FDC1405
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
FDC The feedrate switching function (optional) is:
0 : Disabled.
1 : Enabled.
1410 Dry run rate
[Data type] Word
[Unit of data]
[Valid data range]
Increment system
Unit of data
Valid data range
I
ncremen
t
sys
t
em
U
n
it
o
fd
a
t
a
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Set the dry run rate when the manual feedrate is overridden by 100%.
1411 Cutting feedrate in the automatic mode at poweron
This parameter can be set at Setting screen.
[Data type] Word
[Unit of data]
[Valid data range]
Increment system Unit of data Valid data range
Millimeter machine 1 mm/min 6 to 32767
Inch machine 0.1 inch/min 6 to 32767
When the machine requires little change in cutting feedrate during
cutting, a cutting feedrate can be specified in the parameter. This
eliminates the need to specify a cutting feedrate in the NC program.
The cutting feedrate set by this parameter is valid after the CNC is placed
in the clear state by powerup or a reset until a feedrate is specified by a
program command (F command). After a feedrate is specified by the F
command, the feedrate becomes valid.
1: