PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
52
1722 Rapid traverse feedrate reduction ratio for overlapping rapid traverse blocks
[Data type] Byte axis
[Unit of data] %
[Valid data range] 1 to 100
This parameter is used when rapid traverse blocks are arranged
successively, or when a rapid traverse block is followed by a block that
does not cause, movement. When the feedrate for each axis of a block is
reduced to the ratio set in this parameter, the execution of the next block is
started.
Fh
Fd
Xaxis feedrate
N1 G00 X ; N2 G00 X ;
When the function of overlapping rapid
traverse blocks is enabled
When the function of overlapping rapid
traverse blocks is disabled
Fh
a
Fd
: Rapid traverse feedrate
: Setting of parameter No.1722 (feedrate reduction ratio)
: Feedrate where deceleration is terminated: Fh x a/100
t
NOTE
The parameter No.1722 is effective when parameter
No.1601 #4 (RT0) is set to 1.
1762
Exponential acceleration/deceleration time constant for cutting feed in the
advanced preview feed forward mode
[Data type] Word axis
[Unit of data] 1 ms
[Valid data range]
0 to 4000
This parameter is used to set a time constant for cutting feed exponential
acceleration/deceleration in the advanced preview feed forward mode for
each axis.