B63180EN/02
4. DESCRIPTION OF PARAMETERS
59
NOTE
When an absolute position detector is used, after primary
adjustment is performed or after the absolute position
detector is replaced, this parameter must be set to 0, power
must be turned off and on, then manual reference position
return must be performed. This completes the positional
correspondence between the machine position and the
position on the absolute position detector, and sets this
parameter to 1 automatically.
APCx Position detector
0 : Other than absolute position detector
1 : Absolute position detector (absolute pulse coder)
#7
1816
#6
DM3x
#5
DM2x
#4
DM1x
#3 #2 #1 #0
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Bit axis
DM1x to DM3x Setting of detection multiplier
Set value
DM3x DM2x DM1x
Detection multiplier
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
1/2
1
3/2
2
5/2
3
7/2
4
NOTE
When the flexble feed gear is used, do not use these
parameters. Set the numerator and denominator of DMR to
an appropriate values in parameters 2084 and 2085
respectively.
#7
1817
#6
TAN
#5 #4 #3 #2 #1 #0
NOTE
When this parameter has been set, the power must be
turned off before operation is continued.
[Data type] Bit axis
TAN Tandem control
0 : Not used
1 : Used