4. DESCRIPTION OF PARAMETERS
B63180EN/02
70
IO2 First axis
The basic unit of the FSSB I/O module in group 2 is:
0 : Not used.
1 : Used.
Second axis
The expansion unit of the FSSB I/O module in group 2 is:
0 : Not used.
1 : Used.
NOTE
1 In any group, do not specify that only the expansion unit is
to be used.
2 When this parameter ise set, the power must be turned off
before operation is continued.
PM1 The first pulse module is:
0 : Not used.
1 : Used.
PM2 The second pulse module is:
0 : Not used.
1 : Used.
NOTE
When automatic setting mode is selected for FSSB setting
(when the FMD parameter (bit 0 of parameter No.1902) is set
to 0), parameter No.1905 is automatically set when input is
performed with the FSSB setting screen. When manual
setting 2 mode is selected for FSSB setting (when the FMD
parameter (bit 0 of parameter No.1902) is set to 1),
parameter No.1905 must be set directly. When a pulse
module is used, a connector number must be set in the
corresponding parameter (No.1936 or No.1937).