PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
2. SETTING PARAMETERS FROM MDI
2
2
SETTING PARAMETERS FROM MDI
Follow the procedure below to set parameters.
1 Follow the substeps below to enable writing of parameters.
1-1 To display the setting screen, press the <OFFSET/SETTING>
function key as many times as required, or alternatively press the
<OFFSET/SETTING> function key once, then the [SETING]
section select soft key. The first page of the setting screen appears.
1-2 Position the cursor on PARAMETER WRITE using the
cursor move keys.
SETTING (HANDY) O0001 N00010
PARAMETER WRITE = (0:DISABLE 1:ENABLE)
TV CHECK = 0 (0:OFF 1:ON)
PUNCH CODE = 0 (0:EIA 1:ISO)
INPUT UNIT = 0 (0:MM 1:INCH)
I/O CHANNEL = 0 (0–2:CHANNEL NO.)
0
1-3 Press the [(OPRT)] soft key to display operation select soft keys.
>
MDI STOP *** *** *** 10:03:02
[NO.SRH] [ ON:1 ] [ OFF:0 ] [+INPUT] [INPUT]
Soft key display
(section select)
1-4 To set PARAMETER WRITE= to 1, press the ON:1 soft key,
or alternatively enter 1 and press the INPUT soft key. From now
on, the parameters can be set. At the same time an alarm
condition (P/S100 PARAMETER WRITE ENABLE) occurs in
the CNC.
2 To display the parameter screen, press the <SYSTEM> function key
as many times as required, or alternatively press the <SYSTEM>
function key once, then the [PARAM] section select soft key.
(See 1. Displaying Parameters.)
3 Display the page containing the parameter you want to set, and
position the cursor on the parameter. (See 1. Displaying Parameters.)
4 Enter data, then press the [INPUT] soft key. The parameter indicated
by the cursor is set to the entered data.