PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
77
1960
Start address of the R area to which the DI bit information of the FSSB I/O mod-
ule in group 1 is sent
NOTE
When this parameter ise set, the power must be turned off
before operation is continued.
[Data type] Word
[Valid data range] The range of values that can be set varies with the PMC model.
PMC model Range of the R area that can be set
PMCSB5 0 to 1499, 9100 to 9117
PMCSB6 0 to 2999, 9100 to 9117
1961
Size of the R area to which the DI bit information of the FSSB I/O module in
group 1 is sent
NOTE
When this parameter ise set, the power must be turned off
before operation is continued.
[Data type] Byte
[Unit of data] Byte
[Valid data range] 0 to 4 (if only the basic unit is to be used)
0 to 8 (if both the basic and expansion units are to be used)
1962
Start address of the R area where the bit information to be output to the DO of
the FSSB I/O module in group 1 is stored
NOTE
When this parameter ise set, the power must be turned off
before operation is continued.
[Data type] Word
[Valid data range] The range of values that can be set varies with the PMC model.
PMC model Range of the R area that can be set
PMCSB5 0 to 1499, 9100 to 9117
PMCSB6 0 to 2999, 9100 to 9117

Leave a Reply