B63180EN/02
4. DESCRIPTION OF PARAMETERS
79
1966
Address of the R area to which the DO bit information of the FSSB I/O module
in group 2 is sent
NOTE
When this parameter ise set, the power must be turned off
before operation is continued.
[Data type] Word
[Valid data range] The range of values that can be set varies with the PMC model.
PMC model Range of the R area that can be set
PMCSB5 0 to 1499, 9100 to 9117
PMCSB6 0 to 2999, 9100 to 9117
1967
Size of the R area where the bit information to be output to the DO of the FSSB
I/O module in group 2 is stored
NOTE
When this parameter ise set, the power must be turned off
before operation is continued.
[Data type] Byte
[Unit of data] Byte
[Valid data range] 0 to 3 (if only the basic unit is to be used)
0 to 6 (if both the basic and expansion units are to be used)
The effective DI data of the FSSB I/O module begins at the address set in
parameter No. 1960 or 1964 and its size is specified in parameter No. 1961
or 1965.
The effective DO data of the FSSB I/O module begins at the address set in
parameter No. 1962 or 1966 and its size is specified in parameter No. 1963
or 1967.
If bit 4 (IO1) of parameter No. 1905 is 1, data for the first unit is valid, and
if bit 5 (IO2) of parameter No. 1905 is 1, data for the second unit is valid.
1968
Address of the R area to which information about a DO alarm is output
NOTE
When this parameter ise set, the power must be turned off
before operation is continued.
[Data type] Word
[Valid data range] The range of values that can be set varies with the PMC model.
PMC model Range of the R area that can be set
PMCSB5 0 to 1499, 9100 to 9117
PMCSB6 0 to 2999, 9100 to 9117
Specify the address of the R area to which information about the unit that
encountered an alarm condition (if occurred) is to be reported.R address
information specified in parameter No. 1968