PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
2. SETTING PARAMETERS FROM MDI
3
[Example] 12000 [INPUT]
PARAMETER (FEEDRATE) O0001 N00010
1401 RDR JZR RPD
00000000
1402 JRV
00000000
1410 DRY RUN FEEDRATE
1412 0
1420 RAPID FEEDRATEX 15000
Y 15000
Z 15000
12000
>
MDI STOP *** *** ALM 10:03:10
[NO.SRH] [ ON:1 ] [ OFF:0 ] [+INPUT] [INPUT]
Cursor
Data can be entered continuously for parameters, starting at the selected
parameter, by separating each data item with a semicolon (;).
[Example] Entering 10;20;30;40 and pressing the [INPUT] key assigns values 10,
20, 30, and 40 to parameters in order starting at the parameter indicatedby
the cursor.
5 Repeat steps 6 and 7 as required.
6 If parameter setting is complete, set PARAMETER WRITE= to 0
on the setting screen to disable further parameter setting.
7 Reset the NC to release the alarm condition (P/S100).
If an alarm condition (P/S000 PLEASE TURN OFF POWER) occurs
in the NC, turn it off before continuing operation.