PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
85
The time required to send strobe signals MF, SF, and TF after the M, S,
and T codes are sent, respectively.
M, S, T code
MF, SF, TF signal
Delay time
Fig.4.13 (a) Delay Time of the strobe signal
NOTE
The time is counted in units of 8 ms. If the set value is not
a multiple of eight, it is raised to the next multiple of eight.
[Example]
When 30 is set, 32 ms is assumed.
When 32 is set, 32 ms is assumed.
When 100 ie set, 104 ms is assumed.
3011 Acceptable width of M, S, and T function completion signal (FIN)
Acceptable width of M and T function completion signal (FIN)
[Data type] Word
[Unit of data] 1 ms
[Valid data range] 16 to 32767
Set the minimum signal width of the valid M and T function completion
signal (FIN).
M, S, T code
MF, SF, TF
signal
FIN sigal
Ignored be-
cause shorter
than min.
signal width
Valid because
longer than min.
signal width
Fig.4.13 (b) Valid Width of the FIN (M,S, and T Function Completion)
Signal
NOTE
The time is counted in units of 8 ms. If the set value is not
a multiple of eight, it is raised to the next multiple of eight.