PDF Fanuc Power Mate i-D/H Parameter Manual

B63180EN/02
4. DESCRIPTION OF PARAMETERS
89
#7
OHS3106
#6 #5 #4
OPH
#3 #2 #1 #0
[Data type] Bit
OPH The operation history screen is:
0 : Not displayed.
1 : Displayed.
OHS Operation history sampling is:
0 : Performed.
1 : Not performed.
#7
MDL3107
#6 #5 #4
SOR
#3 #2
DNC
#1 #0
NAM
[Data type] Bit
NAM Program list
0 : Only program numbers are displayed.
1 : Program numbers and program names are displayed.
DNC Upon reset, the program display for DNC operation is:
0 : Not cleared
1 : Cleared
SOR Display of the program directory
0 : Programs are listed in the order of registration.
1 : Programs are listed in the order of program number.
MDL Display of the modal state on the program display screen
0 : Not displayed
1 : Displayed (only in the MDI mode)
#7
JSP3108
#6 #5 #4 #3 #2 #1 #0
[Data type] Bit
JSP On the current position display screen and program check screen, jog feed is:
0 : Not displayed.
1 : Displayed.
NOTE
In manual operation mode, the jog feedrate is displayed. In
automatic operation mode, the dry run feedrate is displayed.
In each case, the feedrate to which a manual feedrate
override has been applied is displayed.
JOG F 8000 PART COUNT 15
RUN TIME 1H17M CYCLE TIME 1H15S
ACT.F 1000 MM/M
AUTO STRT MTN *** 12:34:59
[ ] [ ] [ ] [ ] [ ]
Jog