PDF Fanuc Power Mate i-D/H Parameter Manual

4. DESCRIPTION OF PARAMETERS
B63180EN/02
90
#7
3109
#6 #5
RHD
#4 #3
SFM
#2
IKY
#1 #0
[Data type] Bit
IKY On the tool offset screen, soft key [INPUT] is:
0 : Displayed.
1 : Not displayed.
SFM 0 : Displays the soft keys (menu) for pattern data input screen selection
on page 2 of the offset/setting screen, as is usually done.
1 : Displays the soft keys (menu) for pattern data input screen selection
on page 1 of the offset/setting screen.
NOTE
For details of the pattern data input screen, see Section
4.26, Parameters of Pattern Data Input Function. Pattern
data can be used only with a CRT, PDP, or LCD.
RHD When a manual handle interrupt is generated, the relative position display is:
0 : Not updated.
1 : Updated.
NOTE
This parameter is enabled when the INH parameter (bit 2 of
parameter No.7100) is 1.
#7
NPA
3111
#6 #5 #4 #3 #2
SVP
#1
SPS
#0
SVS
SVSNPA
[Data type] Bit
SVS Servo tuning screen
0 : Not displayed
1 : Displayed
SPS Spindle tuning screen
0 : Not displayed
1 : Displayed
SVP Synchronization errors displayed on the spindle tuning screen
0 : Instantaneous values are displayed.
1 : Peakhold values are displayed.
NPA Action taken when an alarm is generated or when an operator message is
entered
0 : The display shifts to the alarm or message screen.
1 : The display does not shift to the alarm or message screen.

Leave a Reply