4. DESCRIPTION OF PARAMETERS
91
#7
3112
#6 #5
OPH
#4 #3
EAH
#2 #1 #0
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
EAH Messages of the exfernal alam/macro alarm in alarm history:
0 : Not recorded
1 : Recorded
OPH The operation history log function is:
0 : Displayed.
1 : Enable.
#7
3115
#6 #5 #4 #3
NDFx
#2 #1
NDAx
#0
NDPx
[Data type] Bit axis
NDPx Display of the current position for each axis
0 : The current position is displayed.
1 : The current position is not displayed.
NDAx Position display using absolute coordinates and relative coordinates is:
0 : Performed.
1 : Not performed. (Machine coordinates are displayed.)
NDFx To the actual speed display, axis movement data is:
0 : Added.
1 : Not added.
NOTE
Even if the PCF parameter (bit 1 of parameter No.3105) is
set to 0, so as to add PMC controlled axis movement data
to the actual speed display, the movement data for a PMC
controlled axis for which NDFx is set to 1 is not added to the
actual speed display.
#7
MDC3116
#6 #5 #4 #3 #2 #1 #0
MDP
[Data type] Bit
MDP 0 : Does not display the memory card output screen on the ALL I/O
screen.
1 : Displays the memory card output screen on the ALL I/O screen.
MDC 0 : Does not allow all maintenance information to be deleted as a batch by
soft key operation on the maintenance information screen.
1 : Allows all maintenance information to be deleted as a batch by soft
key operation on the maintenance information screen.