4. DESCRIPTION OF PARAMETERS
B63180EN/02
92
#7
3118
#6 #5 #4 #3 #2 #1 #0
AS1
[Data type] Bit
AS1 When the actual spindle speeds (SACT) of the spindle is displayed, the
value is:
0 : The value calculated based on the feedback pulses from the position
coder.
1 : The value calculated from the spindle motor speed (the same as the
spindle speed displayed on the operating monitor screen).
#7
3119
#6
TKY
#5 #4 #3 #2 #1 #0
[Data type] Bit
TKY The MDI keypad uses the:
0 : M series key code for input
1 : T series key code for input
NOTE
The change to this setting takes effect next time the power
is turned on.
3122 Time interval used to record time data in operation history
[Data type] Word
[Unit of data] Minutes
[Valid data range] 0 to 1439
Time data is recorded in operation history at set intervals. When 0 is
specified in this parameter, 10 minutes is assumed as the default.
However, NOTE that time data is not recorded if there is no data to be
recorded at the specified time.
3131 Subscript of each axis name
[Data type] Byte axis
This parameter specifies a subscript (one character) of each axis name
with a code (Power Mate iD twopath control).
The one character subscript specified by this parameter is displayed after
the axis name on the current position screen to discriminate the
coordinates of axes belonging to one path from those of another path.
NOTE
1 This parameter is dedicated to the Twopath control.
2 Specify this parameter for each path.
3 For characters and codes, see the correspondence table in
Appendix 1.
4 If code 0 is specified, paths 1 and 2 are displayed,
respectively, as 1 and 2.