1. DISPLAY AND OPERATION
B--63005EN/02
140
a : Service life
r : Remaining service time
n: Itemname
[Alphanumeric characters*two--byte characters * alphanumeric
characters
q : count type
0 = not to count
1 = count at all times
2 = count during power--on time
3 = count during operation
4 = count during cutting
After the EDIT mode is selected, pressing soft key [READ] causes data
to be registered with item names according to the format in which the data
is input (G10).
Data registration can be done even by executing the format (G10) once
input to the program memory.
This requires a programmable data input option.
NOTE
If the input format (G10) differs from the output format,
registration may fail.
8911
Percentage to the service life of each item displayed on the periodic
maintenance screen
[Data type] Byte
[Unitofdata] 1%
[Valid data range] 0to100
On the periodic maintenance screens, any remaining service time value
smaller than the specified percentage to the service life is displayed in red
for warning purposes.
D Data input
Parameter